7, 10, 13 and 16 kW Air-Cooled Standby Generators


All Guardian generators are UL Listed.
7 kW 10 kW 13 kW 16 kW
  • 7,000 Watts
  • Circuits: 8
  • Generac 410cc OHVIŽ Engine 
  • 10,000 Watts
  • Circuits: 10
  • Electronic Governor
  • Generac 530cc OHVIŽ Engine
  • 13,000 Watts
  • Circuits: 12
  • Electronic Governor
  • Generac 992cc OHVIŽ Engine
  • 16,000 Watts
  • Circuits: 16
  • Electronic Governor
  • Generac 992cc OHVIŽ Engine


 

Generator Set
Model Number 5240 5241 5242 5243
Rated Power (LP / NG) 7/6 kW 10/9 kW 13/13 kW 16/15 kW
Rated Amps @ 60 Hz      
240 V, 1Ř (LP / NG) 29.2/25 42/38 54/54 67/63
3 Phase Models NA NA NA NA
Surge Watts - 240V, 1 Ř 11,040 15,120 22,800 28,080
Surge Amps 46 63 95 117
Engine (Generac OHVI) 410 cc /
Single
530cc /
V-Twin
992cc /
V-Twin
992cc /
V-Twin
Alternator RPM 3600 3600 3600 3600
Enclosure Steel Steel Steel Steel
Whisper Test No No No Yes
Sound Level (dBA @ exercise) 62 63 66 60
(dBA @ normal operation) 62 63 66 66
Dimensions (L" x W" x H") 48x24x28 48x24x28 48x24x28 48x24x28
Automatic Transfer Switch (included) 100 Amp / 8 circuit 100 Amp / 10 circuit 100 Amp / 12 circuit 100 Amp / 16 circuit
Weight 336 375 426 445
         
         
Control Set  
Engine Start Sequence Cyclic cranking: 7 sec. on, 7 sec. rest. 90 sec. maximum duration
Automatic Low Oil Shutdown Standard
Overspeed Shutdown Standard, 72 Hz
Overcrank Protection Standard
Automatic Voltage Regulator with Over-Voltage Protection Standard
Engine Warmup 10 seconds
Engine Cool-Down 1 minute
Safety Fuse Standard
2.5 Amp Timed Trickle Battery Charger Standard
Auto Switch Automatic start on utility failure/7 day exercise
Off Switch Stops unit. Power is removed. Control and charger still operate
Manual / Test (start) Start with starter control, unit stays on. If utility fails, transfer to load takes place
Full Monitoring System Oil pressure, coolant temperature, engine speed, coolant level, cranking time, starter lockout, utility sensing
Shutdown and LED Indicators overspeed and overcrank, low oil pressure, high coolant temperature, low coolant level, low fuel pressure, low battery voltage
Transfer Switch  
No. of Poles 2
Current Rating (amps) 100
Voltage Rating (VAC) 250
Utility Voltage Monitor (fixed)
- Pick-up 70%
- Drop out 60%
Return to Utility Approx. 13 seconds
Exercised 7 minutes weekly Standard
UL Listed Yes
Enclosure Type NEMA 1 (Indoor rated only)
Dimensions (H" x W" x D") 26.5 x 12.5 x 7

 

 

Click here for
Current Specials!

Aerco Heating & Cooling
1530 Pearl St
Anderson, Indiana 46016

765-644-6111
1-888-879-2372

-Furnaces
-Air Conditioners
-Indoor Air Quality
-Maintenance Programs
-Air Duct Cleaning
-Heat Pumps
-Geothermal Systems
-Boilers
-Home Standby Generators

 
Home | About Us | Contact Us | Service | Indoor Air Quality | Furnaces | Air Conditioners | Maintenance Programs | Air Duct Cleaning | Heat Pumps | Geothermal | Boilers | Generators | Thermostats